BWQZS - MERCURIC OXIDE CELL

Product Identification

Product ID:MERCURIC OXIDE CELL
MSDS Date:09/24/1992
FSC:6135
NIIN:00-295-2613
MSDS Number: BWQZS

Responsible Party
DURACELL INC TECHNICAL SALES & MARKETING GROUP
BERKSHIRE INDUSTRIAL PARK BLDG 9
BETHEL, CT 06801
US

Emergency Phone: 203-796-4654/617-449-7600

Info Phone: 203-796-4292

Cage: 90303

Contractor
ENGINEERED ASSEMBLIES AND COMPONENTS CORP
TETERBORO, NJ 07608 US

Telephone: 800-422-8837

Cage: 4J627

Ingredients

POTASSIUM HYDROXIDE (CERCLA)

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 9%

OSHA PEL C 2 MG/M3

ACGIH TLV: C 2 MG/M3; 9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


MERCURIC OXIDE (SARA 302/313) (CERCLA)

CAS: 21908-53-2

RTECS: OW8750000

Fraction By Weight: 35-45%

OSHA PEL 0.1 MG (HG)/M3; Z-2

ACGIH TLV: S,0.025 MG(HG)/M3;96


MERCURY (SARA 313) (CERCLA)

CAS: 7439-97-6

RTECS: OV4550000

Fraction By Weight: <1%

OSHA PEL C, 0.1 MG/M3; Z-2

ACGIH TLV: S,0.025 MG/M3; A4;96

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ZINC (SARA 313) (CERCLA)

CAS: 7440-66-6

RTECS: ZG8600000

Fraction By Weight: 15%

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


MANGANESE DIOXIDE

CAS: 1313-13-9

RTECS: OP0350000

Fraction By Weight: 60%

OSHA PEL 5 MG/M3 CEILING

ACGIH TLV: 5 MG/M3 (AS MN DUST)

Hazards

LD50 LC50 Mixture:NOT SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THESE CHEMICALS ARE CONTAINED IN A
SEALED CAN. RISK OF EXPOSURE OCCURS ONLY IF THE CELL IS
MECHANICALLY OR ELECTRICALLY ABUSED. THE MOST LIKELY RISK IS ACUTE
EXPOSURE WHEN A CELL LEAKS. SKIN CONTACT W ITH CELL CONTENTS CAN
PRODUCE BURNS. EYE CONTACT CAN RESULT IN SEVERE, PERMANENT DAMAGE.
Explanation of Carcinogenicity:PRODUCT CONTAINS NO INGREDIENTS
CURRENTLY CLASSIFIED AS CARCINOGENIC BY NTP, IARC OR OSHA.
Effects of Overexposure:SKIN AND EYE CONTACT WITH CELL CONTENTS MAY
CAUSE CHEMICAL BURNS. AT ELEVATED TEMPERATURES, MERCURY VAPOR MAY
BE GENERATED, WHICH, IF INHALED, CAN PRODUCE MERCURY INTOXICATION.
Medical Cond Aggravated by Exposure:AN ACUTE EXPOSURE WILL NOT
GENERALLY AGGRAVATE ANY MEDICAL CONDITIONS.

First Aid

First Aid:IF LEAKAGE FROM A CELL COMES INTO CONTACT WITH THE SKIN,
FLUSH IMMEDIATELY WITH WATER. FOR EYE CONTACT, FLUSH EYES
IMMEDIATELY WITH COPIOUS WATER FOR 15 MINUTES AND SEE A PHYSICIAN
AT ONCE. FOR INHALA TION OF MERCURY VAPORS, REMOVE TO FRESHAIR.

Fire Fighting

Flash Point:NOT GIVEN
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:NONE SPECIFIED BY MANUFACTURER.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE SELF-CONTAINED
BREATHING APPARATUS WHEN CELLS ARE INVOLVED IN A FIRE.
Unusual Fire/Explosion Hazard:CELLS MAY RELEASE TOXIC MERCURY VAPOR
WHEN THE INTEGRITY OF THE CAN IS BROKEN.

Accidental Release

Spill Release Procedures:AVOID SKIN AND EYE CONTACT. DO NOT INHALE
VAPORS. ABSORB SPILLED CELL CONTENTS WITH APPROPRIATE ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AT ROOM TEMPERATURE.
Other Precautions:AVOID MECHANICAL AND ELECTRICAL ABUSE. DO NOT
RECHARGE. AVOID SHORT CIRCUITS. INSTALL CELLS IN ACCORDANCE WITH
EQUIPMENT INSTRUCTIONS. OBSERVE CORRECT POLARITY WHEN INSTALLING.
REPLACE ALL BATTERIES A T THE SAME TIME.

Exposure Controls

Respiratory Protection:SELF CONTAINED BREATHING APPARATUS WHEN CELLS
ARE INVOLVED IN FIRE.
Ventilation:NORMAL VENTILATION. DURING A FIRE SITUATION, PROVIDE AS
MUCH VENTIALTION AS POSSIBLE.
Protective Gloves:NEOPRENE, RUBBER OR LATEX NITRILE.
Eye Protection:SAFETY GLASSES WHEN HANDLING LEAKERS.
Other Protective Equipment:EMERGENCY EYE WASH STATION AND SHOWER.
Work Hygienic Practices:WASH WITH SOAP AND WATER AFTER HANDLING PRODUCT
AND BEFORE EATING DRINKING OR SMOKING.
Supplemental Safety and Health
DO NOT MIX BATTERY SYSTEMS SUCH AS ALKALINE AND ZINC CARBON. DO NOT
CARRY BATTERIES LOOSE IN POCKET, PURSE OR BAG. KEEP AWAY FROM
CHILDREN. IF SWALLOWED, SEE PHYSICIAN AT ONCE. FOR INFO TREATMENT
CALL NATIONAL CAPITOL POISON CENTER AT 202-625-3333 COLLECT.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:NOT GIVEN
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Decomp Temp:Decomp Text:NOT GIVEN
Vapor Pres:NOT GIVEN
Vapor Density:NOT GIVEN
Spec Gravity:NOT GIVEN
Evaporation Rate & Reference:NOT GIVEN
Solubility in Water:NEGLIGIBLE
Appearance and Odor:SOLID BATTERY

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:DO NOT HEAT, DISASSEMBLE, CRUSH, PUNCTURE
OR RECHARGE
Hazardous Decomposition Products:WHEN HEATED CELLS MAY EMIT HAZARDOUS
MERCURY VAPORS AND CAUSTIC POTASSIUM HYDROXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE
LOCAL, STATE AND FEDERAL REGULATIONS. DO NOT INCINERATE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.